The circuit was designed to provide an alarm system against any form of burglary based on the operation of CMOS 4011 where a high output would only result when any of the input is low.
The zone designed in this circuit contains automatic entry and exit intervals with a bell having its cut off timer. It can also be applicable to other normally open and normally closed switches that contains input devices such as magnetic reed contacts, pressure mats, foil tapes, inertia sensors and passive infrared detectors. The buzzer will sound if the alarm is switched on wherein the loop is in open stage. On theother hand, as the switch turns off, the loop becomes a closed circuit again. The alarm will operate with any type of two-way switch.
The circuit is being powered by a 12 V supply, which is enough for as long as the buzzer, siren, and relay will match the supply input. The basicoperation of the alarm occurs with the interruption of electric current to a relay cause by deenergizing of the relay and making the relay contacts to operate the alarm indicator. The circuit is applicable to a single zone which can consist of a single point of contact. To start the circuit to function, the switch S1 should be set accordingly, but before doing this, all the LED should be properly lighting. Once the switch has been set, there will be an allotted thirty seconds to leave the premises which will trigger the buzzer to sound. It will only stop sounding when the door has been closed. In doing this procedure, it will ensure that the entry and exit operation has been restored effectively. Upon re-entering the premises, there will be 30 seconds time allotment to turn OFF the switch SW1. Failing to do this will trigger and energize the relay and eventually sound the siren. This can be deactivated at any time by turning OFF SW1. The alarm will reset, the relay will de-energize, and the siren will be cut-off once the loop has been restored after 15 minutes.
The delay timers in the circuit depend largely on the values and characteristics of the components used in the circuit, due to the manufacturing tolerances. The entry, exit and bell cut-off timer can be modified by altering the values of resistors R9, R6 and R3 depending on the prerequisite. By decreasing the values, the timer will also decrease; same thing with increasing the values will increase the timing.
A burglar alarm system helps detect unauthorized entry onto a company’s premises. The system sends a signal to a central monitoring center when activated. The monitoring centers provide 24/7 service and will alert the local police to dispatch authorities to the scene. It is a proven fact that the risk of burglary is significantly reduced after a burglar alarm is installed.
Source:www.zen22142.zen.co.uk/Circuits/Alarm/aia.html
Wire-to-board interconnection options from Sullins feature a wide range of sizes and applications
MCC’s TVS series high-power suppressors protect sensitive components from voltage spikes and transients
Evaluation boards that streamline evaluating circuit protection on RS-485 serial device ports
3 years ago: I suggest to go for multi-zone alarm system because they can easily be expanded or reduced in case needed
2 years ago: of course the addition of extra zones should confirm with the budget and maintenance costs...
2 years ago: nice systems
2 years ago: Do you have pcb design for this home alarm circuit? I interested to construct the circuit.